MFZ6(3)-YC SERIES DC WET-VALVE SOLENOID



MFZ6(3)-YC SERIES DC WET-VALVE SOLENOID
Porpose
This series solenoid is applied to single-phase full wave rectifying Dcpover sypply control circuits,which voltage can rach 220V,as a component of the gydraulic solenoids dirctional valve. This solenoid is permitted by BSO company Ltd.In Germany,which is matched for NG6,NG10 of REXROTH bolt connected solenoid directional valve.

Usual Service Conditions
It can be installed randomly.
There is no gas or dust which can corrupt metal or destroy nonconductor.or,it will affect the products lifetime.
The solenoids fit for the character of service as followe:disconnected continuous duty system,intermittent recycled duty system.
The reasonable wave rqnge of supply voltage is betweent 85%-110%(any special requirements is possible).
The protection is IP65 class.

Key Parameters
Code
Rated Voltage£¨V£©
Rated Force £¨N£©
Rated Stroke (mm)
Total Stroke (mm)
Consumed Power(W)
Static Oil Pressure (MPa)
Operating Frequency(T/h)
MFZ6(3)-22YC
12 24 110/220
¡Ý22
2.8
¡Ý6.1
¡Ü30
21.5
12000
MFZ6(3)-37YC
12 24 110/220
¡Ý37
2.8
¡Ý6.1
¡Ü30
31.5
12000
MFZ6(3)-90YC
12 24 110/220
¡Ý90
3.6
¡Ý7.8
¡Ü35
31.5
12000


Purchase Code
Vatve-using Solenoids
DC
Design Code
Rated Force (N)
Wet
MF
Z
6
22/37/90
YC


Externality&Installation Dimensions


Externality&Installation Dimensions




Operating Notice
The socket,which solenoids used,is according to ISO4400 standard.Including two specifications:indicator light&without light.You can choose according to your reuqirments.The voltage of the socket,with indicator light,must conform to the voltage of solenoid itself.
The pushpin of the solenoid is used in adjustment or some times in emergency,but when the backpressure of the system is higher,please use screwdriver to push it,not stride it.The wallop can destroy the pushpin and the surface of the leading hold,orthe solenoid will leak oil or cannot prqosition.
When solenoid is used in double directions,remember the solenoids cannot be energized at the same time in order to prevent the solenoids form burning.
There is a protector of over-current between electrical control systems and solenoids,in order to prevent the solenoids and the electrical component form buming in improderly conditions.

Explantion Of Sample
If client have special requirements,we can dajust the connect dimension,the extended length of push pin,and the supply voltage between solenoids and valve body.
Characteristic curve for reference only.
The main perfonance parameter is obtained in the conditions of lab.Finally explanation and changing of the paramters by HUAXING.